NOT KNOWN DETAILS ABOUT DP50RB

Not known Details About Dp50rb

Not known Details About Dp50rb

Blog Article

The consumer isn't permitted to open the addresses and panel from the process, neither Take note: product disassemble is allowed. To make sure the method overall performance and safety, only Mindray engineers or engineers licensed by Mindray can accomplish upkeep.

iZoom™ permits correct viewing of impression from distance iWorks™ Protocol helps standardize workflow and cut down exam periods

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Notice: Be certain that you could pull out and push into the IO board sockets vertically when pulling out and assembling the IO board assembly to the place in the handle. Take out panhead screws with washers M3X6 (four) used to safe the IO board, then you could potentially just take out the IO board. Web page 116 Take away panhead screws with washers (2 M3X6) that happen to be set on the main unit, choose out the upper baffle and after that pull out two cables connecting the most crucial board to the power module assembly.

The chapter provides the strategy to confirm key operate and performance of products. This is certainly only useful for reference, not preventive execution. Function examining and screening of this component shall be performed by Mindray service engineers as well as consumer collectively. Page sixty six: Common Test

Tend not to use any cables besides the cables provided With all the product by Mindray. three. Make use of the cable delivered with This method to attach the printer. Other cables may possibly lead to electrical shock. Site fifteen: Mechanical Security

Functionality Exam five.5.1 Check Course of action Resolution Detection depth Geometric Posture Accuracy Blackout place exam History the Examination images five.5.two Take a look at Information The picture utilised here is only for reference, follow the impression influence in the actual Take note: situation. Demands: Exhibit: established the distinction and brightness within the scientific application value (or even the default standing) Procedure natural environment: dim room, simulating the medical application setting. Page seventy six In ailment that the transverse resolution testing targets are horizontally exhibited, report the negligible length of two targets that can be Obviously identified. Repeat the operation earlier mentioned with the transverse resolution screening targets at other depths. As shown in figure under. Axial resolution ... Web site seventy seven When utilizing the convex probe, keep the transverse resolution testing targets to notice: be shown near the midline. When utilizing a linear probe with steer operate, do not activate the steer operate when accomplish the transverse resolution examination. Zoom inside the area where the targets Positioned if essential. The diameter from the goal level at a specific depth is equal to the transverse resolution within the depth. Web site seventy eight five.

5.2.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Examination Step: Do changes as how in screening the most depth. File the gap by 20mm Just about every phase on the longitudinal targets line using the Dp50rb login measurement caliper; Pick out the value with the best error (to 20mm), estimate the precision utilizing the formulation under The measurement caliper really should be positioned for the higher fringe of the target, Notice:... Site 79 Transverse geometric positioning precision  Exam Step: Go over the scan surface with the phantom with drinking water or couple gel, Carefully Make contact with the probe Together with the scan floor Change the depth, creating the transverse targets to be shown while in the impression. Adjust the main focus issue for being posited beside the transverse targets (the common is not distinct) Adjust parameters like obtain, TGC, generating each transverse targets for being Obviously shown. Site eighty five.five.2.four Blackout Spot Exam Phase: Go over the scan surface area with the phantom with drinking water or pair gel, gently Get hold of the probe Together with the scan floor Adjust the depth at a lessen benefit, and set the main focus at the nearest location to the scan surface. Reduce the worth of parameters like AP, Attain till the background sound just is often viewed. Page 81: Software Improve And Routine maintenance

Observe: In advance of uploading the log, be certain the ultrasound system continues to be linked to network, or else, the program could alert “could not connect to server” The server (smtp.

Assistance 4D probe; understand the probe by way of the ID code; swap the 4D generate sign by means of the  electrical relay for making the 4D probe get the job done Commonly. 4.two.two Most important board The most crucial board can be divided into two areas: front-conclusion of the leading board and back-close of the principle board.

Site 45 Return “Printer Provider” site, Decide on the corresponding service through the printer checklist and increase the provider. The technique integrates drivers of HP printers, following HP printers are linked, motorists is going to be mounted automatically (about 10s).If auto installation fails, icon will Exhibit on the ideal decrease corner of your screen to alert you that guide installation is important. Website page 46: Network Preset

Get a complete and extended perspective in the anatomical framework as a result of panoramic imaging coupled with velocity indicator and ahead/backward scan skill earning scanning much simpler, smoother and even more controllable.

probe. The image abnormality may be because of Exchange the probe, or the swivel with the 4D probe or even the 4D push change the 4D push board board.

Observe: Over the monitor, the brightness adjustment comes prior to distinction. Following readjusting the keep track of’s contrast and brightness, regulate all preset and peripheral configurations.